Communicate with Supplier? Supplier
Vannes Mr. Vannes
What can I do for you?
Contact Supplier
Pioneer(Dalian)Automation Instrument Co.,Ltd

Pioneer(Dalian)Automation Instrument Co.,Ltd

sales@pioneerinstrument.com

86-411-84174637

Pioneer(Dalian)Automation Instrument Co.,Ltd
HomeProductsUltrasonic Flow MeterWall Mounted Ultrasonic Flow MeterTDS-100F Panel Mount Ultrasonic Flow Meter
TDS-100F Panel Mount Ultrasonic Flow Meter
TDS-100F Panel Mount Ultrasonic Flow Meter
TDS-100F Panel Mount Ultrasonic Flow Meter
TDS-100F Panel Mount Ultrasonic Flow Meter
TDS-100F Panel Mount Ultrasonic Flow Meter
  • TDS-100F Panel Mount Ultrasonic Flow Meter
  • TDS-100F Panel Mount Ultrasonic Flow Meter
  • TDS-100F Panel Mount Ultrasonic Flow Meter
  • TDS-100F Panel Mount Ultrasonic Flow Meter
  • TDS-100F Panel Mount Ultrasonic Flow Meter

TDS-100F Panel Mount Ultrasonic Flow Meter

    Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Delivery Time: 7 Days

Basic Info

Model No.: TDS-100F

Liquid Types: Most Clean Liquids Or Liquids Containing Small Amounts Of Suspended Solids Or Gas Bubbles

Accuracy: 1.5%

Measuring Principle: Transit-Time

Pipe Size: DN15...DN6000

Max. Fluid Temperature: -40...+160℃

Output: 4-20mA/Pulse/RS485

Language: English; Chinese(Other's On Request)

Display: LCD With Backlight, Display Accumulated Flow/heat, Instantaneous Flow/heat, Velocity, Time Etc.

Measurement Period: 500ms

Power Supply: AC220V Or DC24V

Additional Info

Packaging: Cartons Or Wooden Case

Productivity: 10000

Brand: PioneerInstrument

Transportation: Ocean,Land,Air, UPS

Place of Origin: China

Supply Ability: 1000

Certificate: CE

HS Code: 9026100000

Port: Dalian,Dalian,Dalian

Product Description

Introduction

The ultrasonic flow metermain board is suitable for any kinds of transducers,including clamp-on type,insertion type, in-line type,standard in-line type and same kinds of transducers from other manufacturers.the pipe parameters and calibration parameters of water meter and in-line pipe are input by manufacter,users do not need to input any parameter,only need to connect with Flow Meter to work.

The TDS-100F transit-time flowmeter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method where the sound transverses the pipe twice, or W-method where the sound transverses the pipe four times, or in Z-method where the transducers are mounted on opposite sides of the pipe and the sound crosses the pipe once. This selection of the mounting method depends on pipe and liquid characteristics. The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers and measuring the transit time that it takes for sound to travel between the two transducers. The difference in the transit time measured is directly and exactly related to the velocity of the liquid in the pipe, show as follows:

Ultrasonic Flowmeters
Ultrasonic Flow meters

Specifications

Accuracy
Better than ±1.0 %
Repeatability
0.2%
Velocity
±32m/s
Measurement Period
0.5S
Operating Power
85-264VAC

Measurement

Principle


Transit-time measurement principle
Display
LCD with backlight. 2x20 letters.
Keypad
4x4-key membrane keypad with tactile feedback
Signal Input
Two channel three wrie system PT100 platnum resistor input loop,to make heat meter has the function of displaying heat quantity
Three channel 4-20mA input optional,has the ability to input the signals of pressure, liquid level, temperature and so on
Signal Output
One channel isolation 4-20mA or 0-20mA active output.
One channel OCT output(programmed between the pulse width(6-1000ms),default before leaving factory (200ms))
One channel isolation relay output,with positive,negative,net accumulation pulses and different alarm
Others
Automatic memory the positive,negative,net totaliser flow rate and heat quantity of the last 512 days,128 months,10 years

Automatic memory the time of power on/off and flow rate of the last 30 times,realize to replenish by hand or automatically,read the dates through Modbus communication protocol
Protection Level
Mainframe:IP65,IP68(F4 mainframe),transducer:IP68
Transducer
Clamp-on type,insertion type,in-line type

Details

Panel Mounted Ultrasonic Flow Meter

Sensor Type

Panel Type Ultrasonic Flow Meter


Looking for ideal Ultrasonic Flow Measurement Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Ultrasonic Flow Meter Accuracy are quality guaranteed. We are China Origin Factory of Flow Meter Price. If you have any question, please feel free to contact us.